Bettair S is the compact version of Bettair technology. It weighs 5.6 oz (159 g), is IP54-rated and connects over Wi-Fi to measure gases and particulate matter where an outdoor node can't go: transit platforms, plants, control rooms and indoor spaces. Its data flows to the same Bettair Platform.
Best system in an underground railway stationAIRLAB Microsensors Challenge 2025 · AirparifFor years, Bettair technology has shown outdoors that a well-calibrated sensor network can complement reference stations and take measurement to every street. Bettair S brings the same technology to a small, light and easy-to-install format, designed for indoor and semi-enclosed spaces.
By default it measures NO₂, NO, O₃, CO and particles, supports other gases depending on the project and sends data to the Bettair Platform, already used in more than 100 cities.
What it measures
Up to 5 air quality indicators per device, plus absolute humidity.
Gases (standard configuration)
Particles
Optional gases
Best system in the first-ever underground station test
The fifth edition of the AIRLAB Microsensors Challenge, organized by Airparif (the Paris region air quality agency) and AIRLAB, assessed microsensors in an underground railway environment for the first time: a station on the RER network in Île-de-France, in partnership with SNCF Gares & Connexions.
In that scenario, Bettair S was the best-performing system for indoor air monitoring. It is one of Bettair's 9 awards in this edition, which also included the best overall outdoor result in Paris, Accra and Bangalore.
Where it fits
Bettair S is designed for places where you need to measure indoors, close to people.
Transit stations and platforms
The environment where Bettair S was the best system at AIRLAB 2025.
Plants and workshops
Gases and particles inside industrial plants, warehouses and process areas.
Buildings and enclosed spaces
Control rooms, technical offices and covered public spaces.
Outdoors, indoors and on the person
Its clip format lets you fix it to a wall or equipment, or wear it.
Bettair node + Bettair S: inside and outside the facility
For industrial operators, the combination is highly practical. The Bettair node covers the fenceline and surroundings; Bettair S measures indoors, where your people work. With both on the same platform, you can compare indoor and outdoor conditions and trace where each episode comes from.
Bettair node
- Fencelines at plants, construction sites, ports and landfills
- 14+ parameters: gases, particulate matter, noise and weather
- Battery or solar power
Bettair S
- Plants, workshops, warehouses, transit platforms and control rooms
- Gases and particulate matter in 5.1 × 2.7 × 1.5 in
- Wi-Fi, 5 V DC and clip mounting
Bettair node or Bettair S: which one where
| Bettair node | Bettair S | |
|---|---|---|
| Main use | Outdoors: streets, fencelines, low-emission zones | Indoor and semi-enclosed spaces |
| Parameters | 14+: gases, particles, noise and weather | Up to 5 air quality indicators and absolute humidity |
| Power | External: battery or solar panel | 5 V DC, with backup battery (about 2 h) |
| Communication | Direct upload to the cloud | Wi-Fi 2.4 GHz (IEEE 802.11 b/g/n) |
| Format | Node for pole or façade | 5.1 × 2.7 × 1.5 in · 5.6 oz · clip · IP54 |
| Platform | Bettair Platform · REST API | Bettair Platform · REST API |
Technical specifications
Gases
| Gas | Range | LDL | Resolution | Accuracy |
|---|---|---|---|---|
| NO₂ | 0-2,000 ppb | 2 ppb | 0.1 ppb | ±15 ppb |
| O₃ | 0-2,000 ppb | 2 ppb | 0.1 ppb | ±20 ppb |
| NO | 0-20 ppm | 2 ppb | 0.1 ppb | ±4 ppb |
| CO | 0-500 ppm | 30 ppb | 1 ppb | ±30 ppb |
| SO₂ | 0-50 ppm | 10 ppb | 0.1 ppb | ±15 ppb |
| H₂S | 0-50 ppm | 2 ppb | 0.1 ppb | ±10 ppb |
| VOC | 0-100 ppm | 20 ppb | 1 ppb | ±10 ppb |
| NH₃ | 0-60 ppm | 6 ppb | 0.3 ppb | ±10 ppb |
| CH₂O | 0-1,000 ppb | 2 ppb | 0.1 ppb | ±15 ppb |
Particles
| Parameter | Range | LDL | Resolution | Precision | Accuracy |
|---|---|---|---|---|---|
| PM2.5 (µg/m³) | 0-500 | 1 | 1 | ±10% | ±2 µg/m³ |
Device
| Feature | Value |
|---|---|
| Temperature (full accuracy) | 14 to 104 °F (-10 to +40 °C) ambient |
| Humidity (full accuracy) | 15-85% RH |
| Absolute humidity | 0.5-85 g/m³ · ±5% |
| Power supply | 5 V DC |
| Consumption | 0.3 W average · 2.7 W max when charging |
| Backup battery | Li-ion 3.7 V · 660 mAh · about 2 h |
| Communications | Wi-Fi IEEE 802.11 b/g/n · 2.4 GHz |
| Dimensions | 5.1 × 2.7 × 1.5 in (130 × 69.1 × 37 mm; +5 mm with clip) |
| Weight | 5.6 oz (159 g) |
| Enclosure | Polycarbonate · RAL 9010 · UV protection |
| Mounting and protection | Clip · IP54 (dust tight) |
| Sensor lifetime | 2 years with guaranteed data quality; then replaced |
Source: Bettair S datasheet v1.1 (Bettair Cities). Gas configuration is defined per project. Specifications subject to change without notice.
About dnota Air Quality Corp.
dnota Air Quality Corp. brings Bettair technology and dnota's air quality expertise to North America, from reference-grade instrumentation to high-resolution distributed networks for cities, industry, transportation and infrastructure. Based in Coral Gables, Florida.
Related: Bettair sensor nodes · Bettair wins 9 AIRLAB awards
Sources: Bettair S datasheet v1.1 (Bettair Cities); AIRLAB Microsensors Challenge 2025 results (Airparif / AIRLAB). Images: Bettair Cities and dnota.
Need to monitor inside and outside your facility?
Our team helps U.S. operators, agencies and consultants combine Bettair nodes, Bettair S and reference monitors in a single network.